86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


People's Cable Group Co., Ltd

Products >> Overhead Power Transmission Line Bare AAC AAAC ACSR Conductor

Overhead Power Transmission Line Bare AAC AAAC ACSR Conductor

Build Your Online Product Catalogs?



Description
Product Name: Overhead Power Transmission Line Bare AAC AAAC ACSR Conductor
Supply Ability: 120000 Ton
Related proudcts acsr conductor, aaac conductor, aac conductor,
Specifications Hard-drawn Aluminum Conductor Steel Reinforced
Price Term: FOB
Port of loading: Qingdao
Minimum Order 5Ton
Unit Price: USD0.1-45.5

1. Specification

Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn 1350-H19 aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Steel core wire is available in Class A , B or Class C galvanization for corrosion protection. Additional corrosion protection is available through the application of grease to the core or infusion of the completed conductor with grease.

The proportion of steel and aluminium in an ACSR conductor can be selected based on the mechanical strength and current carrying capacity demanded by each application.

ACSR conductors ( Aluminum Conductor Steel Reinforced) are recognized for their record of economy, dependability and favourable strength / weight ratio. ACSR conductors combine the light weight and good conductivity of aluminium with the high tensile strength and ruggedness of steel. In line design, this can provide higher tensions, less sag, and longer ***n lengths than obtainable with most other types of overhead conductors.

2.Features

high Tensile strength
better sag properties
economic design
best suited for transmission lines with long ***ns
3. Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors ,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installation, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-

Contact Us
Company: People's Cable Group Co., Ltd
Contact: Ms. Jessica Chan
Address: No. 13th, Yongding Road, Gongyi, Zhengzhou, China.
Postcode: 451200
Tel: 86 371 55632835
Fax: 86 371 55632837
E-mail:         


Copyright© People's Cable Group Co., Ltd All Rights Reserved.
Tel : 86 371 55632835 Fax : 86 371 55632837
Powered by 86exporter.com